{"created":"2023-06-19T07:40:48.909833+00:00","id":314,"links":{},"metadata":{"_buckets":{"deposit":"893dd11c-77a3-48a2-ad5e-23f55b577fee"},"_deposit":{"created_by":13,"id":"314","owners":[13],"pid":{"revision_id":0,"type":"depid","value":"314"},"status":"published"},"_oai":{"id":"oai:ipnu.repo.nii.ac.jp:00000314","sets":["7","7:56"]},"author_link":["542","292","541"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2022-03","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"49","bibliographicPageStart":"41","bibliographicVolumeNumber":"19","bibliographic_titles":[{"bibliographic_title":"石川看護雑誌"},{"bibliographic_title":"Ishikawa Journal of Nursing","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"本研究の目的は,教育施設内の対面授業学年数別,高頻度接触面の汚染度実態と,次亜塩素酸水を\n使用した接触面の拭き取りの影響をATP 拭き取り検査法により明らかにすることである.実態調査\nの結果は,1・2学年対面授業日での施設内18 箇所の平均汚染度には有意な差はみられなかった.汚\n染度の高い箇所は,施設出入口の引戸の取っ手,講義室内のクレセント・照明スイッチ,トイレの内\n鍵などであった.汚染面の拭き取りでは,アルコール,次亜塩素酸水,水道水を用いた結果,3条件\nの拭き取り前後にはいずれも有意な汚染度の低下がみられた.拭き取り後の条件間の直接比較では,\nアルコールは次亜塩素酸水と水道水に比べて有意に低下し,次亜塩素酸水と水道水には有意な差はみ\nられなかった.アルコールの入手の困難時では,次亜塩素酸水,水道水を用いた接触面の細菌を含め\nた有機物の除去の効果には差がみられないことが示唆された.","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"石川県公立大学法人 石川県立看護大学"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11961976","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1349-0664","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"瀬戸, 清華"},{"creatorName":"セト, キヨカ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"541","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐賀, 香奈美"},{"creatorName":"サガ, カナミ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"542","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中田, 弘子"},{"creatorName":"ナカダ, ヒロコ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"292","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"1000070551167","nameIdentifierScheme":"NRID"},{"nameIdentifier":"70551167","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=70551167"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-04-26"}],"displaytype":"detail","filename":"第19 巻-05.pdf","filesize":[{"value":"1.4 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"第19巻ー05","url":"https://ipnu.repo.nii.ac.jp/record/314/files/第19 巻-05.pdf"},"version_id":"3cf9e648-f187-4a46-9c8b-b9913a613444"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"教育施設","subitem_subject_scheme":"Other"},{"subitem_subject":"高頻度接触面","subitem_subject_scheme":"Other"},{"subitem_subject":"次亜塩素酸水","subitem_subject_scheme":"Other"},{"subitem_subject":"ATP bioluminescence","subitem_subject_scheme":"Other"},{"subitem_subject":"educational facilities","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"frequently contacted surface","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"hypochlorite water","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"ATP bioluminescence","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"(原著論文)教育施設内における高頻度接触面の汚染度実態と 次亜塩素酸水の拭き取りの影響","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"(原著論文)教育施設内における高頻度接触面の汚染度実態と 次亜塩素酸水の拭き取りの影響"},{"subitem_title":"The Actual Level of Contamination on Frequently Contacted Surfaces of Educational Facilities and The Effect of Cleaning with Hypochlorite Water","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"13","path":["7","56"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-04-30"},"publish_date":"2022-04-30","publish_status":"0","recid":"314","relation_version_is_last":true,"title":["(原著論文)教育施設内における高頻度接触面の汚染度実態と 次亜塩素酸水の拭き取りの影響"],"weko_creator_id":"13","weko_shared_id":-1},"updated":"2023-06-19T07:43:05.379335+00:00"}